• +91-8003779056

PAC27P Series (UL-C/US, CE Single Phase)

For phase control system, constant voltage feedback control is equipped as standard.
Space saving type single-phase power regulator with a wide selection of additional optional functions available.
Control achieved under joint use with matching transformer is also available for various usages such as control of heater having alloy, graphite, silicon carbide or pure metal system as its heating element.
*2 Application of CE marking is also available by jointly using the regulator with designated noise filter.



Share:

Feature:

□ Current Capacity: 20, 30, 45, 60, 80, 100A
□ Power Supply: 100 to 120/200 to 240V AC
□ On the condition that the product is used with a noise filter as specified by SHIMADEN, the CE safety standard (EMC Directive) shall be satisfied.
□ As we attach importance to safety aspects, the instrument has a number of alarm circuits including a built-in voltage feedback circuit as a standard function.
□ If you select the current or the voltage control system, or the voltage square switching control system from the optional functions,
control of special types of heaters and transformer loading is possible.

Ordering Information

 

Phase Angle Control (PAC27P)
ITEMS CODE SPECIFICATIONS
SERIES PAC27P   Phase Angle Control Single Phase Power Regulator
Control Input 2   Contact
3   1~5V DC Input Resistance: 200kΩ min.
4   4~20mA DC Receiving Resistance: 100Ω
6   0~10V DC Input Resistance: 200kΩ min.
9   Others (Please consult before ordering)
Power Supply 13-   100~110V AC±10%, 50 / 60Hz
14-   110~120V AC±10%, 50 / 60Hz
15-   200~220V AC±10%, 50 / 60Hz
16-   220~240V AC±10%, 50 / 60Hz
Current Capacity 020   20A
030   30A
045   45A
060   60A
080   80A
100   100A
Feedback Function 0   Constant Voltage Control (standard feature)
1   Constant Current Control
2   Constant Power Control
3   Power linear Control
Current Limit Function 0   None
1   With
  N   None (Internal installation as standard)
External Power Adjuster Contact Input P   External power adjuster
B   Base (low) power adjuster
H   High/Low power adjuster
Current/Voltage Input P   External power adjuster
M   Manual power adjuster
W   External power + Manual power
Heater Break Alarm 0   Without
1   With
Rapid Fuse 0   Without
1   With
Remark 0 Without
9 With (Please consult before ordering.)

note) 1. In order to comply with the EMC Directive, use the noise filter specified by us, which is sold separately, and wire according to the specified method. One filter is required for each PAC27 series thyristor type power regulator. 2. Variable resistance heating elements such as silicon carbide (SiC) heaters have a high negative temperature coefficient (their resistance greatly affected by temperature). During a temperature rise, their resistance falls far below that within the ordinary temperature range, leading to inadequate power. Maintaining output power within an appropriate range at every temperature requires the device’s current capacity to be multiplied by a square root of the heating element’s resistance ratio. To give an example, the approximate resistance ratio of SiC heaters is 1:3, a square root of which is √3, or approx. 1.73. The required current capacity when using those heaters is thus 1.73 times the original capacity. However, since heater deterioration may further widen the ratio, a current capacity even higher than the abovementioned must be selected. As for use of SiC heaters, we recommend about double the original capacity.

Cycle Operation Zero-voltage Switching (PAC27C)
ITEMS CODE SPECIFICATIONS
SERIES PAC27C-   Zero Voltage Switching Single Phase Power Regulator
Control Input 2   Contact
3   1~5V DC Input Resistance: 200kΩ min.
4   4~20mA DC Input Resistance: 100Ω
6   0~10V DC Input Resistance: 200kΩ min.
9   Others (Please consult before ordering)
Power Supply 13-   100~110V AC±10%, 50 / 60Hz
14-   110~120V AC±10%, 50 / 60Hz
15-   200~220V AC±10%, 50 / 60Hz
16-   220~240V AC±10%, 50 / 60Hz
Current Capacity 020   20A
030   30A
045   45A
060   60A
080   80A
100   100A
  N   None (Internal installation as standard)
External Power Adjuster Contact Input P   External power adjuster
B   Base (low) power adjuster
H   High/Low power adjuster
Current/ Voltage Input P   External power adjuster
M   Manual power adjuster
W   External power + Manual power
Heater Break Alarm 0   Without
1   With
Rapid Fuse 0   Without
1   With
Operating Output Indicator 0   Without
1   With (0-1mA DC, 0-100%scale)
Remark 0 Without
9 With (Please consult before ordering.)

Releted Products