PAC18A Series (Single Phase)
The PAC18A series improves the succeeding model PAC18 series of the PAC15 series and is a Thyristor Type Power Regulator of the spread price range in pursuit of a function and performance and safety.
Feature:
o Easy Front Key Setting
o A 7-segment LED Displays Input and Output Values and Various Parameters.
o Slow-Up, Slow-Down Function oCurrent Detection/Alarm Output Function (Optional)
o Data Communication Function (Optional) oUniversal Power Supply (100–240V AC)
o Automatic Frequency Discerning Function (50/60Hz)
o 6 toxic substances, which are subject to RoHS Directive, are contained. However, the amount of toxic substances contained does not exceed standardized values. RoHS: EN50581
Ordering Information
Item | Code | Specifications | Pattern 1 | Pattern 2 | |||||||||||||
Series | PAC18A | Single-Phase Thyristor Power Regulator | ○ Can be changed after purchase |
Can be changed after purchase |
|||||||||||||
Control system | P0– | Phase control/phase angle proportional output | |||||||||||||||
P1– | Phase control/voltage proportional output | ||||||||||||||||
P3– | Phase control/voltage square (electric power) proportional output | ||||||||||||||||
C1– | Cycle calculation zero voltage switching control | ||||||||||||||||
P2– | Phase control/current feedback *Output current detection/alarm output function (optional) |
– | |||||||||||||||
Control input | 3 | Voltage: 1–5V DC, input resistance: 200kΩ, contact: Common | ○ | ○ | |||||||||||||
4 | Current: 4–20mA DC, receiving impedance: 100kΩ, contact: Common | ||||||||||||||||
6 | Voltage: 0–10V DC, input resistance: 200kΩ, contact: Common | ||||||||||||||||
Current capacity | 020– | 20A | ○ | ○ | |||||||||||||
030– | 30A | ||||||||||||||||
045– | 45A | ||||||||||||||||
060– | 60A | ||||||||||||||||
080– | 80A | ||||||||||||||||
100– | 100A | ||||||||||||||||
Current detection/alarm output function (optional) *Phase control/current feedback may be selected in some cases. |
0 | Without | ○ | ○ | |||||||||||||
1 | With | Overcurrent protection, current limit function, alarm output function (power failure/overcurrent/heater break/hardware error) | Required | ||||||||||||||
Data communication function (optional) | 0 | Without | ○ | ○ | |||||||||||||
1 | *Data communication adapter (Data communication adapter (sold separately) can be connected.) |
||||||||||||||||
Remarks | 0 | Without | ○ | ○ | |||||||||||||
9 | With |
Rapid fuse and fuse holder (sold separately)
Name |
PAC18A current capacity |
Fuse type |
Type |
Rapid fuse |
20A/30A |
350GH-50UL |
QSF006 |
45A/60A |
350GH-100UL |
QSF007 |
|
80A/100A |
CR6L-150 |
QSF008 |
|
Fuse holder |
20A–60A |
HT4017+HP40×2 pcs. |
QSH002 |
80A/100A |
CMS-5 |
QSH003 |
|
Rapid fuse with fuse holder |
20A/30A |
350GH-50UL+HT4017+HP40×2 pcs. 1 set |
QSF01F |
45A/60A |
350GH-100UL+HT4017+HP40×2 pcs. 1 set |
QSF01G |
|
80A/100A |
CR6L-150+CMS-5 1 set |
QSF01H |
Noise filter (sold separately)
PAC18A current capacity |
Type |
Rated capacity |
20A |
NF2020C-SDG |
20A |
30A |
NF2030C-SDG |
30A |
45A |
NF2050C-SDG |
50A |
60A |
NF2060C-SDG |
60A |
80A |
NF2080C-SDG |
80A |
100A |
NF2100C-SDG |